Definition
This section has been translated automatically.

Low-dose spiral CT (LDCT) is used primarily as a screening method because of its significantly lower radiation dose. The sensitivity for lung cancer screening ranges from 68.5% to 93.8%, and the specificity ranges from 73.8% to 99.2% (Reck 2023).

General information
This section has been translated automatically.

Applications:

LDCT is particularly well-suited for lung examinations (de Lorenz 2011), but is also used in urology (KI).

The patient does not need to fast for the examination. Radiation exposure is 10%–20% of that of a conventional chest CT and ranges from 0.8 to 1.5 mSv (Gehring 2026).   

Indications:

Low-dose spiral CT is used in particular for patients who require close monitoring, such as

lung cancer screening in relevant risk groups, e.g.,

  • thoseexposed to asbestos
  • Uranium miners (Herold 2025)
  • Smokers—approved in Germany as an annual screening program since April 1, 2026 (Gehring 2026)
  • Follow-up care for patients with resected lung cancer

Patients with chronic lung diseases such as:

Assessable structures:

  • Lung parenchyma
  • Mediastinum
  • Bronchial system
  • Thoracic wall and bony structures
  • Pleural space (Gehring 2026)

Contraindications:

  • Absolute:
    • Pregnancy
    • Acute respiratory decompensation
    • Known or recently treated malignant lung disease
    • Lack of informed consent (Gehring 2026)
  • Relative:
    • Frequent CT scans (cumulative radiation exposure
    • Severe claustrophobia
    • Unclear pulmonary lesions
    • Not belonging to a risk group (Gehring 2026)

Examination Procedure:

Contrast medium is not required for this procedure. The examination takes only a few seconds (Gehring 2026).   

Disadvantages:

LDCT is associated with an increased susceptibility to artifacts and increased image noise (Reh 2023).   

Literature
This section has been translated automatically.

  1. De Lorenzo, C. T. (2011) Low-Dose Multidetector Computed Tomography of the Thorax: Image Quality as a Function of Body Mass. Doctoral dissertation submitted to the Faculty of Medicine at Ludwig Maximilian University of Munich for the degree of Doctor of Medicine
  2. Gehring W G (2026) Low-Dose CT of the Lungs. DocMedicus. https://www.gesundheits-lexikon.com/Medizingeraetediagnostik/Computertomographie-CT/Low-Dose-CT-der-Lunge
  3. Herold G et al. (2025) Internal Medicine. Herold Verlag 405
  4. Kasper D. L., Fauci A. S., Hauser S. L., Longo D. L., Jameson J. L., Loscalzo J., et al. (2015) Harrison’s Principles of Internal Medicine. McGraw-Hill Education
  5. Reck M, Dettmer S, Kauczor H U, Kaaks R, Reinmuth N, Vogel-Claussen J (2023) Lung Cancer Screening with Low-Dose Computed Tomography: Current Status in Germany. Dtsch Arztebl Int 120: 387–392
  6. Reh F et al. (2023) Low-Dose CT. Doc Check Flexikon https://flexikon.doccheck.com/de/Low-Dose-CT

Outgoing links (3)

Asbestosis; Bronchiectasis; Lung carcinoma;

Last updated on: 16.11.2026