Low dose spiral ct
Definition
This section has been translated automatically.
Low-dose spiral CT (LDCT) is used primarily as a screening method because of its significantly lower radiation dose. The sensitivity for lung cancer screening ranges from 68.5% to 93.8%, and the specificity ranges from 73.8% to 99.2% (Reck 2023).
General information
This section has been translated automatically.
Applications:
LDCT is particularly well-suited for lung examinations (de Lorenz 2011), but is also used in urology (KI).
The patient does not need to fast for the examination. Radiation exposure is 10%–20% of that of a conventional chest CT and ranges from 0.8 to 1.5 mSv (Gehring 2026).
Indications:
Low-dose spiral CT is used in particular for patients who require close monitoring, such as
lung cancer screening in relevant risk groups, e.g.,
- thoseexposed to asbestos
- Uranium miners (Herold 2025)
- Smokers—approved in Germany as an annual screening program since April 1, 2026 (Gehring 2026)
- Follow-up care for patients with resected lung cancer
Patients with chronic lung diseases such as:
- emphysema
- Bronchiectasis
- Interstitial lung diseases (Gehring 2026)
Assessable structures:
- Lung parenchyma
- Mediastinum
- Bronchial system
- Thoracic wall and bony structures
- Pleural space (Gehring 2026)
Contraindications:
- Absolute:
- Pregnancy
- Acute respiratory decompensation
- Known or recently treated malignant lung disease
- Lack of informed consent (Gehring 2026)
- Relative:
- Frequent CT scans (cumulative radiation exposure
- Severe claustrophobia
- Unclear pulmonary lesions
- Not belonging to a risk group (Gehring 2026)
Examination Procedure:
Contrast medium is not required for this procedure. The examination takes only a few seconds (Gehring 2026).
Disadvantages:
LDCT is associated with an increased susceptibility to artifacts and increased image noise (Reh 2023).
Literature
This section has been translated automatically.
- De Lorenzo, C. T. (2011) Low-Dose Multidetector Computed Tomography of the Thorax: Image Quality as a Function of Body Mass. Doctoral dissertation submitted to the Faculty of Medicine at Ludwig Maximilian University of Munich for the degree of Doctor of Medicine
- Gehring W G (2026) Low-Dose CT of the Lungs. DocMedicus. https://www.gesundheits-lexikon.com/Medizingeraetediagnostik/Computertomographie-CT/Low-Dose-CT-der-Lunge
- Herold G et al. (2025) Internal Medicine. Herold Verlag 405
- Kasper D. L., Fauci A. S., Hauser S. L., Longo D. L., Jameson J. L., Loscalzo J., et al. (2015) Harrison’s Principles of Internal Medicine. McGraw-Hill Education
- Reck M, Dettmer S, Kauczor H U, Kaaks R, Reinmuth N, Vogel-Claussen J (2023) Lung Cancer Screening with Low-Dose Computed Tomography: Current Status in Germany. Dtsch Arztebl Int 120: 387–392
- Reh F et al. (2023) Low-Dose CT. Doc Check Flexikon https://flexikon.doccheck.com/de/Low-Dose-CT